specs/overview/S_EDGE_DEVICE

Edge Device

Tulip Edge Devices are hardware products that allows customers to integrate external devices with Tulip apps, or depending on the device, independently run NodeRED.

Tulip Edge Devices are designed and programmed by engineers within Tulip, and manufactured by a third party contract manufacturer.

The Edge Device can read and write to devices that have an applicable driver that runs on the software within the Device. It can connect to devices via USB, GPIO (where applicable) or network based protocols.

Edge Device also allow connecting to other machines through OPCUA or MQTT protocols for machine monitoring use cases.

Edge Devices

Tulip currently has two supported Edge Devices (Edge IO & Edge MC)

Edge IO

A wireless, easy-to-implement, low-cost edge device for collecting operational data from devices, machines, PLCs, and sensors and integrating it directly to the Tulip platform. Edge IO devices run the Tulip OS operating system.

NameDescription
CertificationsFCC, CE, TELEC
Dimensions150mm x 130mm x 35mm
Weight30g
Power24V 2 Terminal, Non-locking Phoenix Contact Connector
ProcessorARMv8 4x A53 core; 8GB eMMC; 2 GB DDR3 RAM
Temperature Range (Operating / Storage)0 - 75 ℃ non-condensing
External Displaysmini-HDMI with touch screen compatibility
Industrial I/O4x 24V relay output drivers up to 500mA; 8x Industrial I/O for 5V to 36V digital input
Sensors and Instrumentation24V IEPE current source and input; -3V - 3V Differential Input; 0 - 10V Input; Optional: 24V power source
Peripherals6x USB 2.0; 1x 2-channel integrated Tulip Light Kit engine
Legacy1x RS232 with RTS/CTS; 1x RS485 half-duplex
Networking1x Gigabit Ethernet Phy (native) WAN; 1x 10/100 Ethernet Phy LAN; Dualband 802.11 ac Wireless Internet; LAN IP Range - 10.0.5.0/24
SecurityATECC608A
Trackable AssetsQR Code-based serial “tulip-mfg://EIO-01-XXXXXXXX”; Globally Unique MAC Addresses

Edge MC

Edge MC is a low-cost, low-profile device that enables computing at the edge, accessible and wireless USB connectivity, and machine monitoring. Edge MC devices run the Tulip OS operating system.

NameDescription
CertificationsFCC, CE, CE-RED
Dimensions63mm x 56mm x 35mm
Weight10g
Power5V / 2A USB Micro, 120V/240V (MFG P/N: SMI10-5-V-I38 included)
ProcessorCPU: Allwinner H3 SoC (Quad A7); Storage: 8GB eMMC; RAM: 1GB
Peripherals2x USB 2.0
Legacy1x 5V TTL UART with TX/RX (no RTS/CTS)
LEDs2x Green LEDs; 1x Red LEDs; 4x Link + Speed LEDs for 2x Ethernet
Networking1x 1GB/s Ethernet Phy WAN; 1x 10/100 MB/s Ethernet Phy LAN; Dual Band 802.11 b/g/n Wireless (supports concurrent AP/Station modes); LAN IP Range - 10.0.5.0/24
Trackable AssetsQR Code based serial “tulip-mfg://EMC-01-XXXXXXXX”; Globally Unique MAC Addresses

Page Connections

The Edge Device can be configured and managed through the Device Portal. Once registered to the Tulip Account, it shows up in the Edge Device Page page.

Tests

IDName
QA-T19Pre-auth : 01 - Setup Step 1 - Setting up a password for EdgeIO and EdgeMC
QA-T21Pre-auth : 03 - Setup Step 2 - Network Configuration (DHCP to same Static IP)
QA-T23Post-auth : 01 - Factory Reset via Button
QA-T24Post-auth : 02 - Factory Reset from Device Portal
QA-T25Pre-auth : 07 - Setup Step 3 - Connect Edge Device to Tulip Account
QA-T34Pre-auth : 06 - Setup Step 2 - Network Configuration (different static IP to DHCP)
QA-T36Pre-auth : 05 - Setup Step 2 - Network Configuration (DHCP to different static IP)
QA-T37Pre-auth : 04 - Setup Step 2 - Network Configuration (same Static IP to DHCP)
QA-T38Pre-auth : 11 - HTTP Proxy set up
QA-T40Drivers : 01 - Kolver torque tool
QA-T42Common : 04 - Access Point enabled for Edge Device during factory reset
QA-T43Common : 05 - Factory reset re-enables Access Point
QA-T44Common : 01 - Edge Device Access Point uses network range 10.0.3.x with Edge Device at 10.0.3.1
QA-T45Common : 03 - Edge Device Access Point redirects all URLs to Device Portal
QA-T46Common : 08 - Edge Device boots with Access Point and State Condition indicators during Setup
QA-T48Common : 09 - Edge Device's Access Point can remain disabled after Setup
QA-T49Drivers : 02 - Ohaus scale
QA-T53Common : 11 - Edge Device updated while the Access Point is disabled
QA-T54Common : 12 - Start the Edge Device's Access Point via "A" button (EdgeIO and IO Gateway)
QA-T64Pre-auth : 09 - Mac address for EdgeIO and EdgeMC
QA-T65Common : 14 - Device Portal - Network Configuration persist through reboot
QA-T66Common : 13 - Device Portal - Network Configuration: can add custom DNS server (8.8.8.8.)
QA-T67Common : 15 - Device Portal - Network Configuration reset during Factory reset
QA-T69Common : 02 - Activate Remote Access Session on Edge Device in factory reset state
QA-T70Common : 17 - Activate Remote Access Session via "B" button (no active session)
QA-T72Common : 19 - Remote Access Session activation from Device Portal
QA-T73Common : 20 - Remote Access Session renewal from Device Portal
QA-T74Common : 21 - Stop Remote Access Session from Device Portal
QA-T76Common : 22 - Device Portal disables Remote Access Session when it's disabled from the Terminal
QA-T77Common : 23 - Device Portal recovers when the Remote Access Session no longer exists
QA-T78Common : 25 - Remote Access Session expires after 24h
QA-T79Common : 24- Remote Access Session survives restart
QA-T91Drivers : 03 - GPIO Break Beam
QA-T105Common : 10 - Remote Access Session survives update
QA-T142Post-auth : 21 - Device Portal - Certificate bundle upload
QA-T150Edge Devices Page : 01 - List all Edge devices/IO Gateway devices
QA-T152Edge Devices Page : 03 - Removing an Edge device/IO Gateway device removes it from the Edge Devices page
QA-T154Edge Devices Page : 04 - Open Edge Devices portal
QA-T155Edge Devices Page : 06 - Triggering an OTA (Over the Air) upgrade of an Edge device/IO Gateway device
QA-T156Edge Devices Page : 05 - Cancelling a queued OTA (Over the Air) update
QA-T179Drivers : 18 - Generic Zebra Printer
QA-T187Post-auth : 16 - Diagnostics Test- Network Health
QA-T188Post-auth : 06 - Diagnostics Test- CPU Info
QA-T189Post-auth : 07 - Diagnostics Test- eMMC Manufacturer Info
QA-T190Post-auth : 08 - Diagnostics Test- Front End
QA-T191Post-auth : 09 - Diagnostics Test-OS Info and Hardware Revision
QA-T192Post-auth : 10 - Diagnostics Test-Partition Info
QA-T193Post-auth : 11 - Diagnostics Test- Tulip Packages Info
QA-T194Post-auth : 12 - Diagnostics Test - Firmware Checksum Info
QA-T195Post-auth : 13 - Diagnostics Test- Date Time Info
QA-T197Post-auth : 03 - Logs Test - Generating and Updating
QA-T199Post-auth : 04 - Logs Test - Filters
QA-T200Post-auth : 05 - Logs Test - Word Wrap, Copy to ClipBoard
QA-T284NanoPi specific : 06 - Device Portal login page
QA-T288NanoPi specific : 04 - Connector host basics
QA-T317Post-auth : 22 - Device Portal - Date time set fallback - Edge IO and Edge MC
QA-T395Post-auth : 14 - Diagnostics Test- Device Info
QA-T409NanoPi specific : 01 - WiFi connection
QA-T447Common : 06 - Additional Information panel
QA-T448Common : 07 - Device Portal display QR code and Barcodes
QA-T449Common : 16 - Wired Network Conditions Update when Disconnected
QA-T577Post-auth : 18 - Removing NTP server check
QA-T578Post-auth : 17 - Adding NTP Server check
QA-T621Post-auth : 15 - Diagnostics Test- DHCP Leases
QA-T624NanoPi specific : 02 - Initial Node-Red state after OS deployment
QA-T628Common : 18 - EdgeIO Remote Access Session light
QA-T748Pre-auth : 08 - Setup Step 4 - Quick Configuration
QA-T770Node-Red : 16 - Edge IO OPC UA Node-Red Library Flow connects to Tulip
QA-T832Edge Device Data Source mapping
QA-T842Post-auth : 19 - Enable MQTT Broker
QA-T843Post-auth : 20 - Disable MQTT Broker
QA-T995Drivers : 17 - Edge IO GPIO Pins
QA-T997Drivers : 14 - Phidgets (Humidity/Temperature)
QA-T1001Drivers : 13 - Temp Gun (Humidity/Temperature)
QA-T1010Drivers : 04 - Tulip Light Kit (and Andon Light)
QA-T1022Drivers : 08 - Barcode Scanner
QA-T1023Drivers : 09 - Lascar Humidity/Temperature sensor
QA-T1025Drivers : 10 - InSize and Mitutoyo calipers
QA-T1026Drivers : 11 - Brecknell Scale
QA-T1027Drivers : 12 - Dymo USB Scale
QA-T1028Drivers : 07 - Foot Pedal
QA-T1029Drivers : 05 - Elatec & WaveID RFID card reader
QA-T1100Machine Kit : 04 - Setting up Machine Kit with wired AP during Edge device registration
QA-T1101Machine Kit : 05 - Setup Machine Kit from Quick Configuration page without Node-Red
QA-T1256Machine Kit : 01 - Edge MC Machine Kit box contents
QA-T1287Pre-auth : 10 - Mac address for IOGateway
QA-T1290Module : 1 - Edge PaaS - Module Creation
QA-T1291Module : 2 - Edge PaaS - Module Updates
QA-T1292Module : 3 - Edge PaaS - Module Disable
QA-T1293Module : 4 - Edge Paas - Module Enable
QA-T1327Post-auth : 23 - Device Portal - Date time set fallback - IO Gateway
QA-T1332Other IQC : 3 - IQC - Setting up and testing Current Clamp with Edge MC and Machine Kit Node-RED flow

Requirements

No requirements